Upgrading of the Safety 100 Board
Print
Modified on: Thu, May 16, 2019 at 9:54 AM
Warning: This is an ESD sensitive process. A grounding strap MUST be worn for this process, due to the handling of circuitry. For more information, click here.
|
Changes have been made to the recent version of the Safety 100 board that can cause confusion when installing the updated board on an EZ-Parcels machine. The procedure that must be followed is detailed below.
Removal of the Obsolete Safety 100 Board
Turn off the Safety - This is found behind the tower
| |
Unplug power from the Control Board | |
Disconnect all cables from the Safety 100 board |
|
Remove the board from the machine |
|
Installation of the New Safety 100 Board
Installation of the New Safety 100 Board in the Final Stacker
When the Safety 100 board is replaced in the final stacker of the transport, the procedure that must be followed when connecting the cables will differ in some areas from the procedure that was outlined in Installation of the Safety 100 Board- Cables indicated by numbers 1-5 will be inserted into the same locations shown in section Installation of the Safety 100 Board
- The cable that was plugged into the Safety Next slot in the previous stacker (Number 7) will be carried into the last stacker and plugged into the Safety Previous slot (Number 6)
- The loopback that was present in the Safety Next slot in the board that is being replaced (Number 10) will be removed from the old board and placed into the corresponding location labeled Safety Next on the new board (Number 10)
| Old |
New |