Changing an OTU Row on a Machine

Modified on Mon, Nov 23 at 6:11 PM

Overview

This article walks users through the process of replacing an OTU row on a Chameleon machine.


What is an OTU? The OTU (Omnidirectional Transport Unit) is the part of the Chameleon that diverts (transports) packages off the conveyor. The OTU sits in the OtuSorter section of the machine, along with a section of conveyor.

  • Each OTU has 8 rows (also called slices/strips/stripes).

  • Each row has 8 rollers, driven by two 48 VDC motors:

    • A motor: Turns rollers on (moves packages forward along the conveyor).

    • B motor: Changes the rollers direction to divert packages off the conveyor (left, right, or straight).

  • There are two types of rows: Non-powered Left and Non-powered Right. The name informs which side of the row has the unpowered roller. The two types alternate to reduce friction.

    • Counting from the start of the OTU section, odd rows (1, 3, 5, 7) are Non-powered Left and even rows (2, 4, 6, 8) are Non-powered Right.

    • The row type informs how many jumper cables to expect in Step 6 of the procedure:

      • A Non-powered Left row has one jumper cable, connected to one of its two motors.

      • A Non-powered Right row has two jumper cables, one connected to each motor.


a30a6cca-9c7d-4a0d-b6ef-7cf9339a2ca1.png

Procedure

  1. Before replacing an OTU row, users must successfully put the Chameleon machine into Diagnostics Mode.

    1. Open the PLC API on the Chameleon workstation desktop.

      image-20261108-200854.png
    2. When the PLC opens, users will either see the Home page or the Errors page. In the lower left, find the Machine Mode drop-down menu.

      image-20261108-210622.png
    3. Click the drop-down and change Machine Mode to Diagnostics.
      image-20261108-195021.png
  2. If successful, the machine will sound an alarm, and the stack light will rapidly flash amber.

    image-20261108-195041.png
  3. The Diagnostics screen opens and shows the modules on the Chameleon.
    image-20261108-194933.png
    1. Select the desired divert module and then select Divert Homing. The OTU diverters are in homing position when all the rollers are facing to the left.

      image-20261108-200929.png
      image-20261108-210952.png
  4. When in homing position, the rack pin on each row should be all the way up against the OTU row, as shown below.

    image-20261108-195403.png
  5. Remove the side covers from the frame rails by removing the Torx T30 screws. Use a hand screwdriver with a T30 bit. Do not use a power driver.

    image-20261108-201114.png
  6. Confirm the OTU is in the homing position, and the rack pin is all the way against the OTU row. Then disconnect power to both motors on the row by unplugging the wire connector from each motor (shown below).
    1. A Non-powered Left row has one jumper cable (to one motor). A Non-powered Right row has two jumper cables (one to each motor). When the jumper cables are disconnected, leave them attached to their motors under the OTU row housing. The new OTU row comes with its own jumper cable(s) already connected.

      image-20261109-002047.png
  7. After power has been disconnected from the OTU row, remove the four mounting screws from the OTU row using a T30 bit. There are two screws on each side of the OTU row, shown below. It may be necessary to loosen, but not remove, some screws on the OTU row(s) adjacent to the one that is being removed, as OTU rows sometimes fit tightly and can be difficult to remove if only their own screws are removed.
    1. The OTU row may become too loose and begin slipping downwards. If possible, keep one hand below the OTU row to prevent it from falling out of the machine.

      image-20261108-201253.png
  8. Lift the OTU row up and out of the machine.
    1. Use care during removal and reinstallation to avoid damaging any parts. Users may need to gently tap the bottom of the row with their hand to free it.

  9. Insert the new row and install the four mounting screws.

  10. Reconnect the motor connectors to the new row’s motors.

  11. Re-tighten the screws on the two neighboring rows.

  12. While still in Diagnostics mode, run the row through several left and right divert positions to confirm it diverts correctly. If the OTU row is plugged in but still doesn’t operate correctly, a PLC reset may be necessary.

  13. After the operation of the new OTU row has been verified, reinstall the side covers.

  14. Switch the machine back into production mode. Verify the Stack light returns to normal (green).